Reference number
ISO 18250-7:2018
International Standard
ISO 18250-7:2018
Medical devices — Connectors for reservoir delivery systems for healthcare applications — Part 7: Connectors for intravascular infusion
Edition 1
2018-12
Preview
ISO 18250-7:2018
69729
Indisponible en français
Publiée (Edition 1, 2018)
Cette publication a été révisée et confirmée pour la dernière fois en 2024. Cette édition reste donc d’actualité.

ISO 18250-7:2018

ISO 18250-7:2018
69729
Langue
Format
CHF 151
Convertir les francs suisses (CHF) dans une autre devise

Résumé

This document specifies the interface dimensions and requirements for the design and functional performance of connectors intended to be used to connect intravascular infusion sets to intravascular infusion reservoirs.

This document does not specify the dimensions and requirements for the medical devices or accessories that use these connectors. Such requirements are given in particular international standards for specific medical devices or accessories.

EXAMPLES Medical devices which may use intravascular reservoir connectors are the following:

— Administration ports on IV fluid reservoirs and the mating spikes of IV administration/intravascular infusion sets/lines, e.g., IV bags/containers and the spike inlet ends of IV sets;

— Devices intended to be connected in series between the administration port of IV fluid reservoirs and the mating spikes of IV administration/giving lines;

— Syringes and syringe IV sets utilizing Luer connectors.

The following connectors are excluded from the scope of this document:

— Stoppers for bottles as specified in ISO 8536-2;

— Compounding/admixture ports on IV reservoirs and intended mating devices.

EXAMPLES Rubber stoppers used for injection into the reservoir and the mating pharmacy admixture devices (syringes, needles, reconstitution devices, and other ancillary equipment used to access the compounding or admixture ports).

— The fill ports of non-powered (i.e. elastomeric) pumps.

NOTE 1 Details of alternative spikes that are in common use are located in Annex G for informational purposes.

NOTE 2 Manufacturers are encouraged to incorporate the connectors specified in this document into intravascular infusion medical devices or accessories, even if not currently required by the particular medical device standards. It is expected that when the particular medical device standards are revised, requirements for reservoir connectors, as specified in ISO 18250, will be included.

Informations générales

  •  : Publiée
     : 2018-12
    : Norme internationale confirmée [90.93]
  •  : 1
  • ISO/TC 210
    11.040.25 
  • RSS mises à jour